COOLORANGE SOLUTIONS LTDCudworth, Barnsley

helpdesk@coolorangesolutions.digital Telephone: a call is arranged by e-mail first, because the office is more often on a client site than at a desk.

Four pieces of work, and what each one leaves behind

COOLORANGE SOLUTIONS LTD is an independent information technology consultancy working with small businesses across South Yorkshire from an office in Cudworth, Barnsley. Four kinds of engagement account for nearly everything the company is asked to do, and each one is described here by the document or the tested arrangement it leaves behind.

In practice the fourth item is the one clients remember, because it is the one they open a year later at half past seven in the morning.

Reviewing a system in the order that answers questions fastest

A review is not an inventory, and the difference matters: an inventory lists equipment, whereas a review explains what the business would lose if a given piece of it stopped. The order below is worked through in sequence, because each step narrows the next one.

Nearly every unreviewed network contains one switch that nobody present is able to account for, and it is usually the one carrying the accounts machine.

Planning a migration so that the rollback stays a decision

A migration is the move of a system from where it runs now to where it will run next, and the planning decides whether the move is dull. The plan names every move in order, the person who performs it, the check that confirms it worked, and the point at which the old arrangement is taken out of service. Nothing in it sits on a week grid, because a small business moves in the evenings and on the two Saturdays when the yard is quiet.

The rehearsal comes before the cutover. A rehearsal copies the data into the new system while the old one keeps running, so that the copy time is measured on the real circuit and the awkward files are found early. The cutover is the short window in which the business stops using one system and starts using the other, and it is agreed in hours, because that number governs every other number in the plan.

The rollback position is written down before the cutover begins: the condition under which the move is abandoned, and the state the old system must be left in so that abandoning it takes minutes. In practice a written rollback is almost never used, which is the argument for writing it, since the version held only in somebody's head is the version that fails at two in the morning.

Engagements are shaped around that structure and not around a fixed package. Some clients want the review and the plan, and will move the system themselves; others want the move performed and the notes handed over. The second costs more only because it takes longer.

Network and backup design, and the restore test that carries a date

Network design means deciding the addressing, the equipment and the layout on purpose instead of by accretion. Addressing is the scheme that gives each device its number on the network, and it is worth setting deliberately, because a scheme chosen once is readable by a stranger and a scheme grown over eight years is readable by nobody. Wireless coverage is planned from the shape of the building and the metal inside it, since a warehouse and an office of equal floor area need different numbers of access points.

Backup design starts from two figures the client supplies: how much work the business is willing to redo after a failure, and how long it is able to stand still while the system is rebuilt. The first sets how often copies are taken, and the second sets where they are kept, because a copy held offsite is safer and slower to bring back than a copy held in the building.

The restore test makes the rest of it true. On an agreed date a copy is taken from the backup, opened on separate equipment, and checked against something the client recognises, such as last month's invoices. The date, the file, the time the restore took and the outcome all go into the notes, whichever way the outcome went, which means the client owns a record of a restore that happened.

A backup nobody has ever restored is a filing habit, and it is a good one, but it is worth knowing which of the two you are paying for.

As found, as handed over

The two drawings below occupy one frame. Drag the handle, or use the slider beneath it, to wipe between a network as it is commonly found on a first visit and the same network once it has been documented. Both show the same six devices; only the knowledge of them differs.

??? ??? six devices, no map Circuitmeasured, not assumed Switch .18 ports, 3 in use Server .10records and backup source Desks .40 to .60named per user Access point .20office and yard six devices, every one named

As found As handed over

Working out the rate a cutover window demands

The window is agreed with the client first, and the rate has to follow from it. Enter the volume to be moved and the hours actually available, and the arithmetic below solves for the sustained transfer rate that window requires. Tick the read-back box when the data is to be read back and compared afterwards, because the same volume then crosses the link twice.

Megabytes to move200 × 1024 = 204,800 MB

Seconds in the window6 × 3600 = 21,600 s

Volume crossing the link204,800 MB, one pass

Sustained rate required204,800 ÷ 21,600 = 9.48 MB/s

The same rate in circuit units9.48 × 8 = 75.85 Mbit/s

Largest volume that fits the same window at three link rates a client is able to check on their own circuit

100 Mbit/s, that is 12.5 MB/s12.5 × 21,600 ÷ 1024 = 263.7 GB

300 Mbit/s, that is 37.5 MB/s37.5 × 21,600 ÷ 1024 = 791.0 GB

1 Gbit/s, that is 125 MB/s125 × 21,600 ÷ 1024 = 2,636.7 GB

Every figure on this panel is a unit conversion of the two numbers entered above: one gigabyte is treated as 1024 megabytes, one hour as 3600 seconds and one byte as 8 bits. The result states what the agreed window demands of a link; it is arithmetic and not a measurement, so what a circuit actually sustains is established during the rehearsal.

What is left with you

An engagement closes when the following four artefacts exist, are readable by somebody who was not present while the work was done, and are held by the client and not by the consultancy.

Those four documents are the point of the work. A client who holds them is able to instruct any competent engineer, including one who is not this company, which is a reasonable definition of a handover.